[Answer ID: 15469]

What does the message on the LCD display indicate when the ERROR LED is turned on? (TS3000 series)

Created 08/25/2014 14:50  |   Updated 08/25/2014 15:34

Refer to the following boxes which is listed the meaning of LED blinking and the resolution.

LCD Message

Description

Corrective Action

BOOT FAIL

Hard drive not found.

Contact Buffalo technical support for assistance.

SYSTEM Error E04
Can’t Load Krnl!

The firmware is corrupted.

Contact Buffalo technical support for assistance.

UPS E10
Dependent Mode

The TeraStation is running on the UPS battery due to a power outage. The system will now be shut down safely.

Check that power is being supplied to the UPS, and if there are no problems, turn on the TeraStation.

SYSTEM I10
TOO HOT !

A rise in the system temperature may have exceeded the allowable safety value.

Move the TeraStation to a cool location. Do not place objects in the area around the TeraStation.

SYSTEM Error E11
Fan Failure

An error occurred in the fan speed.

Check that no foreign objects or dust are clogging the fan. If any foreign objects or dust are found, use a pair of tweezers, air duster, or other tool to remove them. If the error is displayed again, contact Buffalo technical support for assistance.

SYSTEM Error E12
Cooling Failure

A rise in the system temperature may have exceeded the allowable safety value.

Do not place objects in the area around the TeraStation. Also, move the TeraStation to a cool location.

RAID Arrayx E14
Can’t Mount

RAID array X cannot be mounted.

Run the RAID array disk check in Settings.

HDx Error E16
HDx Not Found

Unable to find hard drive X.

Hard drive X may be disconnected or may have failed. After shutting down, reinstall the hard drive.

HDx Error E22
HDx Can’t Mount

Mounting of hard drive X failed.

Format the hard drive. After formatting, if the error still appears after rebooting, replace the hard drive. If the error is displayed again, contact Buffalo technical support for assistance.

FailOver E27
LostBackupTarget

Unable to find the backup TeraStation.

In the main TeraStation’s settings, navigate to Backup - Failover to reconfigure the backup TeraStation for failover.

HDx Broken E30
Replace the DISK

An error occurred, so hard drive X was removed from the RAID array.

Replace hard drive X.



Details


Products

OS / Hardware

Was this answer helpful?
Please tell us how we can make this answer more useful.

Refine your search

Select Product / OS & Hardware

      Enter Keywords or a specified ID